The garage doors were clad in the same material to help them match and their deep inset provides a deep shadow.
Over cladding garage roof.
The process when overcladding an asbestos cement roof it will also be necessary in most cases to include a layer of insulation to meet current day building regulations.
Verges can then be created by using a ridge piece or alternatively nailing the final corrugation over a raised barge board.
The first stage is to fix a framework to hold the metal sheets in place directly to the purlins underneath the asbestos cement roof sheets.
This course of action causes minimal disruption to business activities and also provides added insulation to the roof construction.
Roof sheathing comes in grid marked 4 by 8 foot sheets and should be installed perpendicular to the frame.
Start at the opposite end to the prevailing winds again and allow overlaps of 125mm.
This creates a risk since over cladding contractors often say you don t need to empty your garage and with all this drilling you may contaminate the contents with asbestos fibres.
As the weight of the system is less than that of the potential water absorbed by the existing asbestos cement and fibre cement sheets there is no requirement for structural calculations.
The typical thickness range for sheathing is 3 8 to 3 4 inch.
Think about impression earlier mentioned.
Now this is the 1st graphic.
If you believe thus i l l explain to you.
Sheathing should be a minimum of 19 32 inch thick.
This is so frequent that some contractors make a living solely fixing cut edge corrosion which can occur very quickly on a metal roof.
In order to do this any over cladding must have so many anchors bolts fixings down into the beams below the cement asbestos roof sheets that there will be a considerable amount of drilling of the existing asbestos cement roof sheets.
Top garage roof cladding garage roof cladding welcome in order to the website in this moment we ll teach you in relation to keyword.
Install ridges and verges.
Never attach roof sheathing with staples.
It therefore requires no additional structural supports.
At an existing 1970s home and garage in cap cod the whole house including the garage had its dated exterior cladding removed replaced with vertical strips of kebony clear siding and a freedom gray copper standing seam metal roof.
8d ring shank nails should be used instead.
Leaving the exiting roof material in place eliminates the need for expensive removal actions whilst the over cladding exercise will also eliminate the risks associated with asbestos exposure.
Filon over roofing is lightweight yet strong and is manufactured to the same profile as the existing roof.
Complete peace of mind.