Under e2 as1 all parapets must be flashed with a cap flashing having a 5 cross fall to prevent water accumulation.
Parapet roof flashing details.
Detail drawing pdf pdf 195 kb.
3 3a surface mounted counter flashing detail.
Parapet with coping and parasolo flashing.
Where parapets are being retained flashing the top is essential.
Roof area divider curb type.
The roofing squares are locked into a 20 oz.
This detail may be used where wall heights are 24 48 inches above roof surface.
Membranes continuous under the parapet flashing.
Detail drawing dwg.
Paraguard expansion joint roof to roof with parasolo flashing.
Any modifications or changes to the certainteed drawings are the sole responsibility of the roof consultant architect designer or builder and certainteed assumes no responsibility or liability for any such modifications or changes.
The roof composition flashing extends up the cant strip over the coping and part way down its face under the copper flashing.
Ct 06 base flashing wall cover on wood parapet wall.
The counterflashing laps the base flashing a minimum of 3.
On the opposite side a continuous copper edge strip is attached to the coping and the lower edge is bent to form a drip.
Sp 35 usp sp vent stack flashing detail.
Paraguard expansion joint roof to wall with parasolo flashing.
Air control layer continuity.
High wall flashing detail 10 wide sheets.
Sp 30 usp sp alternate high wall flashing detail.
The roof side of the copper is cleated to the nailable cant strip.
Sp 34 usp sp scupper flashing detail.
All of the good series of parapet details presented follow the baker principles and a little bit of other stuff figure 12a figure 12b figure 13 figure 14 and figure 15.
Mf 13 3 1 1 metal cap flashing joints mf 13 3 1 2 metal cap flashing inside corner mf 13 3 1 3 metal cap flashing parapet to wall transition site formed note.
This detail shows a flashing condition at a vertical wall or parapet.
Parapet with paraguard coping and parasolo flashing.
Copper base flashing which extends at least 8 up the wall.
Water control layer continuity.
Wsrca suggests for walls 24 inches and taller that wall cladding be considered in lieu of membrane wall flashings per detail tp 8a.
Parapet wall with edge grip.
High wall flashing detail 5 wide sheets.
Parapet with plywood sheathing and parasolo flashing.
Sp 31 usp sp parapet wall with usp sp clad metal flashing detail.
The following pages are currently under construction mf 13 3 1 4 metal cap flashing parapet to wall transition shop formed.
Wall base termination detail.
Typical roofing details autocad files.
Where no structural damage has occurred and the cladding is sound the parapet should be cap flashed as shown below.
Sp 33 usp sp standard roof drain flashing detail for fastened systems.